University of Florida - Replacement of the Rabon Plant Cooling Towers 4 and 5 - FY27-ITN-001 (2026)
- Due
- Aug 20, 2026
- Deadline passed
- Posted
- Jul 9, 2026
- Primary contact
- Mike Loudis
- (352) 294-1154
The 30-second brief
University of Florida is seeking competitive proposals for the disposal and replacement of two 2-cell Marley cooling towers (cooling towers 4 and 5) at the Lacy C. Rabon Chilled Water Plant located at 1858 Mowry Rd, Building 0473, Gainesville, FL 32608. The scope includes structural replacement utilizing the existing 40ft x 50ft basin footprint, mechanical piping connections, metal fan blades, gearboxes, fill, drift eliminators, vibration switches, oil level switches, fan motors with 120V space heaters, and staircase/access integration. The project has an estimated budget of $950,000.00 and a strict completion window starting November 1, 2026, with full operation required no later than April 1, 2027. A mandatory pre-bid site visit is scheduled for July 17, 2026, at 9:30 AM EDT, and submissions close on August 20, 2026, at 3:00 PM EDT.
2 – 480V 60HP fan motors and associated fans, 2 – 120V vibration switches, 2 – 120V motor space heaters, 4 – pole lights on top of tower, Vibration switches, Oil level switch, Safety switches, Mechanical piping and mechanical connections, Cooling tower fans and gearboxes, Cooling tower fill, Drift eliminators, Fan/gearbox lube oil system, Staircase and access for the new cooling tower, Engineered drawings
Technical proposal including ability to complete work no later than April 1, 2027, Pricing Proposal, Evidence of satisfactory performance on five (5) similar projects within the past five (5) years, References (Trade, Bank, Surety), Professional services offered and support options, Agreement with UF standard Terms & Conditions and technical specifications, Material and workmanship warranty
Hear what University Of Florida plans next before it's posted.
Get alerts freeFree account · 30-second setup · No credit card
Summary
University of Florida is seeking competitive proposals for the disposal and replacement of two 2-cell Marley cooling towers (cooling towers 4 and 5) at the Lacy C. Rabon Chilled Water Plant located at 1858 Mowry Rd, Building 0473, Gainesville, FL 32608.
The scope includes structural replacement utilizing the existing 40ft x 50ft basin footprint, mechanical piping connections, metal fan blades, gearboxes, fill, drift eliminators, vibration switches, oil level switches, fan motors with 120V space heaters, and staircase/access integration. The project has an estimated budget of $950,000.00 and a strict completion window starting November 1, 2026, with full operation required no later than April 1, 2027. A mandatory pre-bid site visit is scheduled for July 17, 2026, at 9:30 AM EDT, and submissions close on August 20, 2026, at 3:00 PM EDT.
EVALUATION CRITERIA
Technical proposal including ability to complete work no later than April 1, 2027, Pricing Proposal, Evidence of satisfactory performance on five (5) similar projects within the past five (5) years, References (Trade, Bank, Surety), Professional services offered and support options, Agreement with UF standard Terms & Conditions and technical specifications, Material and workmanship warranty
REQUIRED DELIVERABLES
14- 2 – 480V 60HP fan motors and associated fans
- 2 – 120V vibration switches
- 2 – 120V motor space heaters
- 4 – pole lights on top of tower
- Vibration switches
- Oil level switch
- Safety switches
- Mechanical piping and mechanical connections
- Cooling tower fans and gearboxes
- Cooling tower fill
- Drift eliminators
- Fan/gearbox lube oil system
- Staircase and access for the new cooling tower
- Engineered drawings
REQUIRED ATTACHMENTS
14- Certification of Proposal
- Technical proposal and timeframe
- Pricing proposal
- Evidence of satisfactory performance on five similar projects
- Trade References
- Bank References
- Surety references
- List of subcontractors for work valued at more than $10
- 000
- Proof of corporation/LLC/partnership registration
- Proof of liability insurance coverage
- Safety information and EMR rating
- Minimum material and workmanship warranty
- List of concerns with University terms and conditions
- Submit to
- [email protected]
- Scope location
- Gainesville, FL
- Reported agency
- University of Florida
Questions about this RFP
How do I respond to this RFP from University Of Florida?
Review the full solicitation document for submission requirements, evaluation criteria, and deadlines. The submission deadline is August 20, 2026. The solicitation specifies required deliverables that must be addressed in your response. Be sure to include all required attachments as outlined in the solicitation. Submissions should be delivered to: [email protected]. For questions, contact Mike Loudis.
Can small businesses or minority-owned firms bid on this RFP?
Most government agencies, including University Of Florida in FL, encourage participation from small businesses, minority-owned, women-owned, and disadvantaged business enterprises (MBE/WBE/DBE). Check the full solicitation for any small business participation goals.
What happens after the RFP submission deadline?
After the deadline, the issuing agency reviews all submissions against the stated evaluation criteria. This typically includes a compliance check, technical evaluation, cost analysis, and may involve oral presentations with shortlisted vendors.
Can I ask questions about this solicitation before submitting?
Yes, most solicitations allow vendors to submit questions during a designated period. The primary contact is Mike Loudis at (352) 294-1154. Questions and answers are typically shared with all prospective bidders.
What are the key deliverables?
The solicitation specifies the following deliverables: 2 – 480V 60HP fan motors and associated fans, 2 – 120V vibration switches, 2 – 120V motor space heaters, 4 – pole lights on top of tower, Vibration switches, Oil level switch, Safety switches, Mechanical piping and mechanical connections, Cooling tower fans and gearboxes, Cooling tower fill, Drift e. Proposals should clearly address how each deliverable will be met.
Show 4 more questions
What are the evaluation criteria for this solicitation?
This solicitation includes specific evaluation criteria that will be used to score proposals. The criteria include: "Technical proposal including ability to complete work no later than April 1, 2027, Pricing Proposal, Evidence of satisfactory performance on five (5) similar projects within the past five (5) years, R..." Vendors should carefully align their proposals with each criterion to maximize their score.
Where can I find more RFPs from University Of Florida?
All active and historical solicitations from University Of Florida are tracked and searchable. As a higher ed agency, University Of Florida regularly publishes solicitations. Visit the agency profile to see current open bids, past contracts, vendor relationships, and decision-maker contacts.
What documents are required to bid on this RFP?
Requirements vary by solicitation, but common documents include a technical proposal, cost/price proposal, proof of insurance, relevant certifications, past performance references, and any forms specified in the solicitation. This solicitation specifically requires the following attachments: Certification of Proposal, technical proposal and timeframe, pricing proposal, evidence of satisfactory performance on five similar projects, Trade References, Bank References, and Surety references,. Review the full document from University Of Florida for the complete list.
What is the scope of this project?
This solicitation defines a specific project scope. The scope covers the following locations: Gainesville, FL. Review the full solicitation for detailed scope requirements.