City of Winter Garden - Construction Services for Teacup Springs Septic To Sewer Conversion RFP 2027
- Due
- Jan 12, 2027
- 57 days left
- Primary contact
- Jim Monahan
- (407) 656-4111
The 30-second brief
The City of Winter Garden is requesting proposals for construction services for the Teacup Springs Septic To Sewer Conversion project in Orange, FL. Work includes erosion and turbidity control, manholes, gravity sewers, jack and bore, sewer service connections, force main by directional drill, valves, road base and asphalt paving, concrete driveways and sidewalks, and unsuitable material excavation. The submission deadline is January 12, 2027, at 2:00 PM, with questions accepted until January 5, 2027, at 4:00 PM. Plans are available from the Owner, and local funding requirements may apply.
1 LS erosion & turbidity control/npdes requirements; 11 EA manholes; 4650 LF gravity sewers (8" sdr 26 pvc); 50 LF jack and bore (20" casing with 8" carrier); 133 EA sewer service connection; 306 LF 2-inch force main by directional drill; 18 EA 8" valve and valve box; 33, 400 SY road base (10") and asphalt with tack coat (2-inch); 300 SY concrete driveway (6" thick reinforced); 500 SY concrete sidewalk (4" thick reinforced); 4000 CY unsuitable material excavation
Bids like this start as pre-RFPs. Get the next ones early.
Get matched pre-RFPs freeFree account · 30-second setup · No credit card
Summary
The City of Winter Garden is requesting proposals for construction services for the Teacup Springs Septic To Sewer Conversion project in Orange, FL. Work includes erosion and turbidity control, manholes, gravity sewers, jack and bore, sewer service connections, force main by directional drill, valves, road base and asphalt paving, concrete driveways and sidewalks, and unsuitable material excavation.
The submission deadline is January 12, 2027, at 2:00 PM, with questions accepted until January 5, 2027, at 4:00 PM. Plans are available from the Owner, and local funding requirements may apply.
REQUIRED DELIVERABLES
11- 1 LS erosion & turbidity control/npdes requirements
- 11 EA manholes
- 4650 LF gravity sewers (8" sdr 26 pvc)
- 50 LF jack and bore (20" casing with 8" carrier)
- 133 EA sewer service connection
- 306 LF 2-inch force main by directional drill
- 18 EA 8" valve and valve box
- 33, 400 SY road base (10") and asphalt with tack coat (2-inch)
- 300 SY concrete driveway (6" thick reinforced)
- 500 SY concrete sidewalk (4" thick reinforced)
- 4000 CY unsuitable material excavation
- Submit to
- 300 W Plant St, Winter Garden, FL, 34787
- Scope location
- Orange, FL
Questions about this RFP
How do I respond to this RFP from City of Winter Garden?
Review the full solicitation document for submission requirements, evaluation criteria, and deadlines. The submission deadline is January 12, 2027. The solicitation specifies required deliverables that must be addressed in your response. Submissions should be delivered to: 300 W Plant St, Winter Garden, FL, 34787. For questions, contact Jim Monahan.
Can small businesses or minority-owned firms bid on this RFP?
Most government agencies, including City of Winter Garden in FL, encourage participation from small businesses, minority-owned, women-owned, and disadvantaged business enterprises (MBE/WBE/DBE). Check the full solicitation for any small business participation goals.
What happens after the RFP submission deadline?
After the deadline, the issuing agency reviews all submissions against the stated evaluation criteria. This typically includes a compliance check, technical evaluation, cost analysis, and may involve oral presentations with shortlisted vendors.
Can I ask questions about this solicitation before submitting?
Yes, most solicitations allow vendors to submit questions during a designated period. The primary contact is Jim Monahan at (407) 656-4111. Questions and answers are typically shared with all prospective bidders.
What are the key deliverables?
The solicitation specifies the following deliverables: 1 LS erosion & turbidity control/npdes requirements; 11 EA manholes; 4650 LF gravity sewers (8" sdr 26 pvc); 50 LF jack and bore (20" casing with 8" carrier); 133 EA sewer service connection; 306 LF 2-inch force main by directional drill; 18 EA 8" valve and valve box; 33, 400 SY road base (10") and. Proposals should clearly address how each deliverable will be met.
Show 4 more questions
Where can I find more RFPs from City of Winter Garden?
All active and historical solicitations from City of Winter Garden are tracked and searchable. As a city agency, City of Winter Garden regularly publishes solicitations. Visit the agency profile to see current open bids, past contracts, vendor relationships, and decision-maker contacts.
Is this solicitation still open for submissions?
Based on the posted deadline of January 12, 2027, this solicitation appears to still be accepting submissions. Deadlines may change through amendments or addenda, so always verify the current status directly with the issuing agency before preparing your response.
What documents are required to bid on this RFP?
Requirements vary by solicitation, but common documents include a technical proposal, cost/price proposal, proof of insurance, relevant certifications, past performance references, and any forms specified in the solicitation. Review the full document from City of Winter Garden for the complete list.
What is the scope of this project?
This solicitation defines a specific project scope. The scope covers the following locations: Orange, FL. Review the full solicitation for detailed scope requirements.