The 30-second brief

What they're buying

Windham Northeast Supervisory Union seeks competitive proposals from mechanical, HVAC, and environmental remediation contractors for boiler replacement, pumping infrastructure, and control upgrades at Grafton Elementary School in Grafton, VT. The project involves replacing the existing Peerless SC-07 oil-fired cast-iron hot-water boiler with either an oil-fired or high-efficiency liquid propane (LP) boiler system (Base Option A or B), including asbestos abatement of breeching insulation, temporary containment, air monitoring, and hazardous material disposal. Scope also includes hydraulic, pump, and trim upgrades (Grundfos Magna 3 circulators, injection/boiler protection pump, Amtrol Extrol expansion tank) and optional direct digital controls (DDC) ranging from boiler room DDC to building-wide DDC integrating classroom unit ventilators and cabinet unit heaters. The 14,820 sq ft facility, constructed in 1980, requires compliance with Vermont Department of Health and EPA regulations, bonding requirements, and submission of proof of licensing, references, subcontractor lists, and project schedules. Proposals are due by November 23, 2026, at 3:00 PM EST.

What you must deliver

Base Option A: Oil-Fired Boiler Replacement; Base Option B: Liquid Propane (LP) High-Efficiency Conversion; Environmental Remediation & Asbestos Abatement (CIM-1); Hydraulic, Pump & Trim Upgrades (ECM-3); Control Option 1: Integrated Local Controls (ECM-4); Control Option 2: Boiler Room Direct Digital Controls (ECM-5); Control Option 3: Building-Wide Direct Digital Controls (ECM-6)

How it's scored

Total capital cost and long-term operating efficiency, Compliance with technical specifications and asbestos abatement protocols, Contractor qualifications, experience with educational facilities, and local/regional presence, Feasibility of proposed project timeline and execution plan

Hear what Windham Northeast Union Elementary School District plans next before it's posted.

Get alerts free

Free account · 30-second setup · No credit card

Summary

Windham Northeast Supervisory Union seeks competitive proposals from mechanical, HVAC, and environmental remediation contractors for boiler replacement, pumping infrastructure, and control upgrades at Grafton Elementary School in Grafton, VT. The project involves replacing the existing Peerless SC-07 oil-fired cast-iron hot-water boiler with either an oil-fired or high-efficiency liquid propane (LP) boiler system (Base Option A or B), including asbestos abatement of breeching insulation, temporary containment, air monitoring, and hazardous material disposal.

Scope also includes hydraulic, pump, and trim upgrades (Grundfos Magna 3 circulators, injection/boiler protection pump, Amtrol Extrol expansion tank) and optional direct digital controls (DDC) ranging from boiler room DDC to building-wide DDC integrating classroom unit ventilators and cabinet unit heaters. The 14,820 sq ft facility, constructed in 1980, requires compliance with Vermont Department of Health and EPA regulations, bonding requirements, and submission of proof of licensing, references, subcontractor lists, and project schedules. Proposals are due by November 23, 2026, at 3:00 PM EST.

EVALUATION CRITERIA

6
  • Total capital cost and long-term operating efficiency
  • Compliance with technical specifications and asbestos abatement protocols
  • Contractor qualifications
  • Experience with educational facilities
  • Local/regional presence
  • Feasibility of proposed project timeline and execution plan

REQUIRED DELIVERABLES

7
  • Base Option A: Oil-Fired Boiler Replacement
  • Base Option B: Liquid Propane (LP) High-Efficiency Conversion
  • Environmental Remediation & Asbestos Abatement (CIM-1)
  • Hydraulic, Pump & Trim Upgrades (ECM-3)
  • Control Option 1: Integrated Local Controls (ECM-4)
  • Control Option 2: Boiler Room Direct Digital Controls (ECM-5)
  • Control Option 3: Building-Wide Direct Digital Controls (ECM-6)

REQUIRED ATTACHMENTS

5
  • Proof of Licensing & Certifications
  • Experience & References
  • Subcontractor List
  • Project Schedule
  • Warranty & Service
Submit to
Email inbox, shown to Civic IQ members.Sign up free to see it
Scope location
Grafton, VT
Projected sq ft
14,820 sq ft
Reported agency
Windham Northeast Supervisory Union

Questions about this RFP

How do I respond to this RFP from Windham Northeast Union Elementary School District?

Review the full solicitation document for submission requirements, evaluation criteria, and deadlines. The submission deadline is November 23, 2026. The solicitation specifies required deliverables that must be addressed in your response. Be sure to include all required attachments as outlined in the solicitation. Submissions go to an agency email inbox; Civic IQ members see the exact address. For questions, contact Andrew Haas.

Can small businesses or minority-owned firms bid on this RFP?

Most government agencies, including Windham Northeast Union Elementary School District in VT, encourage participation from small businesses, minority-owned, women-owned, and disadvantaged business enterprises (MBE/WBE/DBE). Check the full solicitation for any small business participation goals.

What happens after the RFP submission deadline?

After the deadline, the issuing agency reviews all submissions against the stated evaluation criteria. This typically includes a compliance check, technical evaluation, cost analysis, and may involve oral presentations with shortlisted vendors.

Can I ask questions about this solicitation before submitting?

Yes, most solicitations allow vendors to submit questions during a designated period. The primary contact is Andrew Haas at (802) 463-9958. Questions and answers are typically shared with all prospective bidders.

What are the key deliverables?

The solicitation specifies the following deliverables: Base Option A: Oil-Fired Boiler Replacement; Base Option B: Liquid Propane (LP) High-Efficiency Conversion; Environmental Remediation & Asbestos Abatement (CIM-1); Hydraulic, Pump & Trim Upgrades (ECM-3); Control Option 1: Integrated Local Controls (ECM-4); Control Option 2: Boiler Room Direct Digit. Proposals should clearly address how each deliverable will be met.

Show 4 more questions

What are the evaluation criteria for this solicitation?

This solicitation includes specific evaluation criteria that will be used to score proposals. The criteria include: "Total capital cost and long-term operating efficiency, Compliance with technical specifications and asbestos abatement protocols, Contractor qualifications, experience with educational facilities, and..." Vendors should carefully align their proposals with each criterion to maximize their score.

Where can I find more RFPs from Windham Northeast Union Elementary School District?

All active and historical solicitations from Windham Northeast Union Elementary School District are tracked and searchable. As a school agency, Windham Northeast Union Elementary School District regularly publishes solicitations. Visit the agency profile to see current open bids, past contracts, vendor relationships, and decision-maker contacts.

What documents are required to bid on this RFP?

Requirements vary by solicitation, but common documents include a technical proposal, cost/price proposal, proof of insurance, relevant certifications, past performance references, and any forms specified in the solicitation. This solicitation specifically requires the following attachments: Proof of Licensing & Certifications, Experience & References, Subcontractor List, Project Schedule, Warranty & Service. Review the full document from Windham Northeast Union Elementary School District for the complete list.

What is the scope of this project?

This solicitation defines a specific project scope. The scope covers the following locations: Grafton, VT. The total projected area is 14820 sq ft. Review the full solicitation for detailed scope requirements.

Work in government? Get Civic IQ free →

The coverage behind every signal

agencies covered
275,000+agencies covered
buying signals a week
400,000+buying signals a week
decision makers
2.6M+decision makers
in government spend tracked
$14T+in government spend tracked

Trusted by 200+ enterprise teams

Motive logoVeritone logoTerraCycle logoCyvl logoWithersRavenel logoDerivita logoSafeTouch logoIANS Research logoSewerAI logoProdigy Education logoEPR Fireworks logoFlow Labs logoCloudpermit logoMotive logoVeritone logoTerraCycle logoCyvl logoWithersRavenel logoDerivita logoSafeTouch logoIANS Research logoSewerAI logoProdigy Education logoEPR Fireworks logoFlow Labs logoCloudpermit logoMotive logoVeritone logoTerraCycle logoCyvl logoWithersRavenel logoDerivita logoSafeTouch logoIANS Research logoSewerAI logoProdigy Education logoEPR Fireworks logoFlow Labs logoCloudpermit logoMotive logoVeritone logoTerraCycle logoCyvl logoWithersRavenel logoDerivita logoSafeTouch logoIANS Research logoSewerAI logoProdigy Education logoEPR Fireworks logoFlow Labs logoCloudpermit logo

Start finding government buyers today.

Signals from 275,000+ state, local and education agencies, months before the RFP. Free to start.

No credit card required