QUOTEOPEN
Save

City of Austin - Spare Main Generator Breaker for Decker Creek Power Station - IFQ 1100 CPG1095 (2026)

City of Austin city logoCity of Austin city
Due
Dec 2, 2026
5 days left
Posted
Nov 24, 2026
Primary contact
Christopher Gorski
(512) 978-1527

The 30-second brief

What they're buying

The City of Austin, Austin Energy is seeking quotes for one complete spare medium-voltage generator breaker assembly suitable for power generation application at Decker Creek Power Station in Austin, TX. The procurement requires a new or refurbished, factory-tested breaker compliant with ANSI/IEEE standards for 15 kV class switchgear equipment, specifically replacing or matching an ITE Imperial Corporation Model 11 breaker (Serial 95757-A1-3-8A). Required deliverables include datasheets, certified drawings, installation/operation/maintenance manuals, FAT test reports, recommended spare parts lists, and services such as Factory Acceptance Test (FAT), commissioning and startup support, and maintenance schedule. Responses are due by December 2, 2026, at 2:00 PM via City of Austin eResponse.

What you must deliver

One complete spare medium-voltage generator breaker assembly (ITE Imperial Corporation, Model 11, Serial 95757-A1-3-8A or equivalent), Datasheets and certified drawings, Installation, Operation, And maintenance manuals, FAT test reports, Recommended spare parts list (2-year and 5-year), Factory Acceptance Test (FAT), Commissioning and startup support, Maintenance schedule

How it's scored

Lowest Offer meeting minimum requirements

5 days left to submitDue Dec 2

Bids like this start as pre-RFPs. Get the next ones early.

Get matched pre-RFPs free

Free account · 30-second setup · No credit card

Summary

The City of Austin, Austin Energy is seeking quotes for one complete spare medium-voltage generator breaker assembly suitable for power generation application at Decker Creek Power Station in Austin, TX. The procurement requires a new or refurbished, factory-tested breaker compliant with ANSI/IEEE standards for 15 kV class switchgear equipment, specifically replacing or matching an ITE Imperial Corporation Model 11 breaker (Serial 95757-A1-3-8A).

Required deliverables include datasheets, certified drawings, installation/operation/maintenance manuals, FAT test reports, recommended spare parts lists, and services such as Factory Acceptance Test (FAT), commissioning and startup support, and maintenance schedule. Responses are due by December 2, 2026, at 2:00 PM via City of Austin eResponse.

EVALUATION CRITERIA

Lowest Offer meeting minimum requirements

REQUIRED DELIVERABLES

One complete spare medium-voltage generator breaker assembly (ITE Imperial Corporation, Model 11, Serial 95757-A1-3-8A or equivalent), Datasheets and certified drawings, Installation, Operation, And maintenance manuals, FAT test reports, Recommended spare parts list (2-year and 5-year), Factory Acceptance Test (FAT), Commissioning and startup support, Maintenance schedule

REQUIRED ATTACHMENTS

3
  • Price Sheet
  • Signed Offer Sheet
  • Employer Certification Wage Theft Ordinance – Responsibility Criteria
Submit to
Mailing address, shown to Civic IQ members.Sign up free to see it
Scope location
Austin, TX
Reported agency
City of Austin

Questions about this QUOTE

How do I respond to this Quote from City of Austin city?

Review the full solicitation document for submission requirements, evaluation criteria, and deadlines. The submission deadline is December 2, 2026. The solicitation specifies required deliverables that must be addressed in your response. Be sure to include all required attachments as outlined in the solicitation. Submissions go to a mailing address at the agency; Civic IQ members see the exact address. For questions, contact Christopher Gorski.

Can small businesses or minority-owned firms bid on this Quote?

Most government agencies, including City of Austin city in TX, encourage participation from small businesses, minority-owned, women-owned, and disadvantaged business enterprises (MBE/WBE/DBE). Check the full solicitation for any small business participation goals.

What happens after the Quote submission deadline?

After the deadline, the issuing agency reviews all submissions against the stated evaluation criteria. This typically includes a compliance check, technical evaluation, cost analysis, and may involve oral presentations with shortlisted vendors.

Can I ask questions about this solicitation before submitting?

Yes, most solicitations allow vendors to submit questions during a designated period. The primary contact is Christopher Gorski at (512) 978-1527. Questions and answers are typically shared with all prospective bidders.

What are the key deliverables?

The solicitation specifies the following deliverables: One complete spare medium-voltage generator breaker assembly (ITE Imperial Corporation, Model 11, Serial 95757-A1-3-8A or equivalent), Datasheets and certified drawings, Installation, Operation, And maintenance manuals, FAT test reports, Recommended spare parts list (2-year and 5-year), Factory Acce. Proposals should clearly address how each deliverable will be met.

Show 5 more questions

What are the evaluation criteria for this solicitation?

This solicitation includes specific evaluation criteria that will be used to score proposals. The criteria include: "Lowest Offer meeting minimum requirements" Vendors should carefully align their proposals with each criterion to maximize their score.

Where can I find more RFPs from City of Austin city?

All active and historical solicitations from City of Austin city are tracked and searchable. As a city agency, City of Austin city regularly publishes solicitations. Visit the agency profile to see current open bids, past contracts, vendor relationships, and decision-maker contacts.

Is this solicitation still open for submissions?

Based on the posted deadline of December 2, 2026, this solicitation appears to still be accepting submissions. Deadlines may change through amendments or addenda, so always verify the current status directly with the issuing agency before preparing your response.

What documents are required to bid on this Quote?

Requirements vary by solicitation, but common documents include a technical proposal, cost/price proposal, proof of insurance, relevant certifications, past performance references, and any forms specified in the solicitation. This solicitation specifically requires the following attachments: Price Sheet, signed Offer Sheet, Employer Certification Wage Theft Ordinance – Responsibility Criteria. Review the full document from City of Austin city for the complete list.

What is the scope of this project?

This solicitation defines a specific project scope. The scope covers the following locations: Austin, TX. Review the full solicitation for detailed scope requirements.

Work in government? Get Civic IQ free →

The coverage behind every signal

agencies covered
275,000+agencies covered
buying signals a week
400,000+buying signals a week
decision makers
2.6M+decision makers
in government spend tracked
$14T+in government spend tracked

Trusted by 200+ enterprise teams

Motive logoVeritone logoTerraCycle logoCyvl logoWithersRavenel logoDerivita logoSafeTouch logoIANS Research logoSewerAI logoProdigy Education logoEPR Fireworks logoFlow Labs logoCloudpermit logoMotive logoVeritone logoTerraCycle logoCyvl logoWithersRavenel logoDerivita logoSafeTouch logoIANS Research logoSewerAI logoProdigy Education logoEPR Fireworks logoFlow Labs logoCloudpermit logoMotive logoVeritone logoTerraCycle logoCyvl logoWithersRavenel logoDerivita logoSafeTouch logoIANS Research logoSewerAI logoProdigy Education logoEPR Fireworks logoFlow Labs logoCloudpermit logoMotive logoVeritone logoTerraCycle logoCyvl logoWithersRavenel logoDerivita logoSafeTouch logoIANS Research logoSewerAI logoProdigy Education logoEPR Fireworks logoFlow Labs logoCloudpermit logo

Start finding government buyers today.

Signals from 275,000+ state, local and education agencies, months before the RFP. Free to start.

No credit card required