Oklahoma Municipal Power Authority - Transformer and LTC/Regulator Oil Lab and Sampling Services - RFQ 2026
Oklahoma Municipal Power AuthorityUtility District · Edmond, OK- Due
- Dec 3, 2026
- 13 days left
- Posted
- Nov 10, 2026
- Contract term
- 1 year
- Primary contact
- Alex Dobson
- (405) 359-2512
The 30-second brief
Oklahoma Municipal Power Authority (OMPA) is requesting competitive quotes for transformer, LTC, and regulator oil lab analysis, sampling services, and related tasks across multiple member cities in Oklahoma. The scope involves an estimated 129 annual oil samples plus re-samples, providing clean vials and containers, safety gear, tools, pulling samples at specified intervals, optional sampling port installations and drain extensions, optional top-off service using dry Type II inhibited mineral oil or Shell Diala, and annual filter changes on Perry transformer LTC filtration systems using Pall part# UE210AZ08Z. Certified testing must include PCB tests, transformer condition tests (hydrogen, methane, ethane, ethylene, acetylene, carbon monoxide, carbon dioxide, nitrogen, oxygen, moisture, dielectric breakdown voltage, acid number, interfacial tension, color number, power factor, oxidation inhibitor, particle analysis, furan analysis with estimated DP), and LTC/regulator condition tests with metal-in-oil analysis. Proposals are due by 5:00 PM CST on Thursday, December 3, 2026, submitted to Alex Dobson via email or at 2701 West I-35 Frontage Road, Edmond, OK 73013. The contract term is one year with annual renewal options for up to five years. Evaluation criteria include best value criteria (total cost, technology, experience, financial stability, schedule compliance), specification compliance, testing facility quality, and RFQ responsiveness.
Transformer oil lab analysis, Sampling services, Annual sampling for 129 samples, Optional sampling port installations, Optional oil top-off service, Annual filter changes for 2 Perry Transformer LTC filtration systems, PCB testing, Transformer condition testing, LTC/regulator condition testing
The Best Value Criteria (total cost, quality and technology, experience and prior performance, financial stability, schedule compliance), Compliance with bid specifications, Certification and quality of testing facilities, Responsiveness to this RFQ
Bids like this start as pre-RFPs. Get the next ones early.
Get matched pre-RFPs freeFree account · 30-second setup · No credit card
Summary
Oklahoma Municipal Power Authority (OMPA) is requesting competitive quotes for transformer, LTC, and regulator oil lab analysis, sampling services, and related tasks across multiple member cities in Oklahoma.
The scope involves an estimated 129 annual oil samples plus re-samples, providing clean vials and containers, safety gear, tools, pulling samples at specified intervals, optional sampling port installations and drain extensions, optional top-off service using dry Type II inhibited mineral oil or Shell Diala, and annual filter changes on Perry transformer LTC filtration systems using Pall part# UE210AZ08Z. Certified testing must include PCB tests, transformer condition tests (hydrogen, methane, ethane, ethylene, acetylene, carbon monoxide, carbon dioxide, nitrogen, oxygen, moisture, dielectric breakdown voltage, acid number, interfacial tension, color number, power factor, oxidation inhibitor, particle analysis, furan analysis with estimated DP), and LTC/regulator condition tests with metal-in-oil analysis. Proposals are due by 5:00 PM CST on Thursday, December 3, 2026, submitted to Alex Dobson via email or at 2701 West I-35 Frontage Road, Edmond, OK 73013. The contract term is one year with annual renewal options for up to five years. Evaluation criteria include best value criteria (total cost, technology, experience, financial stability, schedule compliance), specification compliance, testing facility quality, and RFQ responsiveness.
EVALUATION CRITERIA
The Best Value Criteria (total cost, quality and technology, experience and prior performance, financial stability, schedule compliance), Compliance with bid specifications, Certification and quality of testing facilities, Responsiveness to this RFQ
REQUIRED DELIVERABLES
9- Transformer oil lab analysis
- Sampling services
- Annual sampling for 129 samples
- Optional sampling port installations
- Optional oil top-off service
- Annual filter changes for 2 Perry Transformer LTC filtration systems
- PCB testing
- Transformer condition testing
- LTC/regulator condition testing
REQUIRED ATTACHMENTS
Itemized pricing for all requested services (Exhibit A), Certification documentation for the testing lab and equipment calibration records, A signed acknowledgment of exceptions
- Submit to
- Email inbox, shown to Civic IQ members.Sign up free to see it
- Duration
- 72 months
- Scope location
- Edmond, OK
Questions about this RFQ
How do I respond to this RFQ from Oklahoma Municipal Power Authority?
Review the full solicitation document for submission requirements, evaluation criteria, and deadlines. The submission deadline is December 3, 2026. The solicitation specifies required deliverables that must be addressed in your response. Be sure to include all required attachments as outlined in the solicitation. Submissions go to an agency email inbox; Civic IQ members see the exact address. For questions, contact Alex Dobson.
Can small businesses or minority-owned firms bid on this RFQ?
Most government agencies, including Oklahoma Municipal Power Authority in OK, encourage participation from small businesses, minority-owned, women-owned, and disadvantaged business enterprises (MBE/WBE/DBE). Check the full solicitation for any small business participation goals.
What happens after the RFQ submission deadline?
After the deadline, the issuing agency reviews all submissions against the stated evaluation criteria. This typically includes a compliance check, technical evaluation, cost analysis, and may involve oral presentations with shortlisted vendors.
Can I ask questions about this solicitation before submitting?
Yes, most solicitations allow vendors to submit questions during a designated period. The primary contact is Alex Dobson at (405) 359-2512. Questions and answers are typically shared with all prospective bidders.
What are the key deliverables?
The solicitation specifies the following deliverables: Transformer oil lab analysis, Sampling services, Annual sampling for 129 samples, Optional sampling port installations, Optional oil top-off service, Annual filter changes for 2 Perry Transformer LTC filtration systems, PCB testing, Transformer condition testing, LTC/regulator condition testing. Proposals should clearly address how each deliverable will be met.
Show 6 more questions
What are the evaluation criteria for this solicitation?
This solicitation includes specific evaluation criteria that will be used to score proposals. The criteria include: "The Best Value Criteria (total cost, quality and technology, experience and prior performance, financial stability, schedule compliance), Compliance with bid specifications, Certification and quality..." Vendors should carefully align their proposals with each criterion to maximize their score.
Where can I find more RFPs from Oklahoma Municipal Power Authority?
All active and historical solicitations from Oklahoma Municipal Power Authority are tracked and searchable. As a utility district agency, Oklahoma Municipal Power Authority regularly publishes solicitations. Visit the agency profile to see current open bids, past contracts, vendor relationships, and decision-maker contacts.
What is the contract term for this solicitation?
The anticipated contract term is 1 year. Contract terms may include renewal options.
Is this solicitation still open for submissions?
Based on the posted deadline of December 3, 2026, this solicitation appears to still be accepting submissions. Deadlines may change through amendments or addenda, so always verify the current status directly with the issuing agency before preparing your response.
What documents are required to bid on this RFQ?
Requirements vary by solicitation, but common documents include a technical proposal, cost/price proposal, proof of insurance, relevant certifications, past performance references, and any forms specified in the solicitation. This solicitation specifically requires the following attachments: Itemized pricing for all requested services (Exhibit A), Certification documentation for the testing lab and equipment calibration records, A signed acknowledgment of exceptions. Review the full document from Oklahoma Municipal Power Authority for the complete list.
What is the scope of this project?
This solicitation defines a specific project scope. The scope covers the following locations: Edmond, OK. Review the full solicitation for detailed scope requirements.