Holmes County Consolidated School District Controlled Access Security System RFP 2026
- Due
- Dec 4, 2026
- 10 days left
- Posted
- Nov 19, 2026
- Primary contact
- Michelle Cage
- (662) 834-2175
The 30-second brief
Holmes County Consolidated School District is requesting sealed proposals for a Controlled Access Security System that includes a stand-alone video surveillance recording system at selected schools and offices in the Holmes County School District. The project scope involves furnishing and installing complete operational access control and video intercom systems across facilities including Central Office Entrances, S.V. Marshall Elementary/Middle School, W.M. Dean Elementary School, W.L. Sullivan Middle School, Career and Technical Education Center, GWR Academy, and Durant Elementary School. Required hardware and software components include IP network infrastructure, MonitorCast v4 Server, IP Door Controllers, PoE network switches, WV-S25500-F6L indoor/outdoor PoE cameras with 5MP UHD video, HID Signo readers, prox cards, electric strikes, magnetic locks, and video-intercom systems. Proposals are due by 2:00 p.m. on December 4, 2026. A pre-bid site walk-through is scheduled for November 30, 2026 at 9:00 a.m. Written questions are due by December 2, 2026 at 4:30 p.m. Minimum eligibility requirements include a minimum of three years of experience, relevant past installs, financial stability, and compliance with all applicable laws.
Controlled Access and Video Surveillance Security System, Access control panels, Proximity readers, Motion request-to-exit devices, Exit buttons, Desk door-release buttons, Magnetic locks, Electric strikes, Prox cards, WV-S25500-F6L indoor/outdoor PoE cameras, Five-port PoE network switches, Video-intercom systems, MonitorCast v4 Server, IP Door Controllers, Door sub-controllers
Experience (20 Points), Project Design (20 Points), Cost Efficiency (40 Points), Program Operations (20 Points)
Bids like this start as pre-RFPs. Get the next ones early.
Get matched pre-RFPs freeFree account · 30-second setup · No credit card
Summary
Holmes County Consolidated School District is requesting sealed proposals for a Controlled Access Security System that includes a stand-alone video surveillance recording system at selected schools and offices in the Holmes County School District.
The project scope involves furnishing and installing complete operational access control and video intercom systems across facilities including Central Office Entrances, S.V. Marshall Elementary/Middle School, W.M. Dean Elementary School, W.L. Sullivan Middle School, Career and Technical Education Center, GWR Academy, and Durant Elementary School. Required hardware and software components include IP network infrastructure, MonitorCast v4 Server, IP Door Controllers, PoE network switches, WV-S25500-F6L indoor/outdoor PoE cameras with 5MP UHD video, HID Signo readers, prox cards, electric strikes, magnetic locks, and video-intercom systems. Proposals are due by 2:00 p.m. on December 4, 2026. A pre-bid site walk-through is scheduled for November 30, 2026 at 9:00 a.m. Written questions are due by December 2, 2026 at 4:30 p.m. Minimum eligibility requirements include a minimum of three years of experience, relevant past installs, financial stability, and compliance with all applicable laws.
EVALUATION CRITERIA
REQUIRED DELIVERABLES
15- Controlled Access and Video Surveillance Security System
- Access control panels
- Proximity readers
- Motion request-to-exit devices
- Exit buttons
- Desk door-release buttons
- Magnetic locks
- Electric strikes
- Prox cards
- WV-S25500-F6L indoor/outdoor PoE cameras
- Five-port PoE network switches
- Video-intercom systems
- MonitorCast v4 Server
- IP Door Controllers
- Door sub-controllers
REQUIRED ATTACHMENTS
12- Vendor Profile
- Production Proposal
- Implementation Plan
- Budget narrative/cost proposal
- Manufacturer model numbers and quantities
- Installation schedule and estimated duration
- Bidder's relevant experience with K-12 access-control and video-intercom installations
- Mississippi licensing
- Insurance
- Qualifications
- Warranty terms
- Statement of exclusions/assumptions/alternates/deviations
- Submit to
- Mailing address, shown to Civic IQ members.Sign up free to see it
- Scope location
- Lexington, MS
Questions about this RFP
How do I respond to this RFP from Holmes County Consolidated School District?
Review the full solicitation document for submission requirements, evaluation criteria, and deadlines. The submission deadline is December 4, 2026. The solicitation specifies required deliverables that must be addressed in your response. Be sure to include all required attachments as outlined in the solicitation. Submissions go to a mailing address at the agency; Civic IQ members see the exact address. For questions, contact Michelle Cage.
Can small businesses or minority-owned firms bid on this RFP?
Most government agencies, including Holmes County Consolidated School District in MS, encourage participation from small businesses, minority-owned, women-owned, and disadvantaged business enterprises (MBE/WBE/DBE). Check the full solicitation for any small business participation goals.
What happens after the RFP submission deadline?
After the deadline, the issuing agency reviews all submissions against the stated evaluation criteria. This typically includes a compliance check, technical evaluation, cost analysis, and may involve oral presentations with shortlisted vendors.
Can I ask questions about this solicitation before submitting?
Yes, most solicitations allow vendors to submit questions during a designated period. The primary contact is Michelle Cage at (662) 834-2175. Questions and answers are typically shared with all prospective bidders.
What are the key deliverables?
The solicitation specifies the following deliverables: Controlled Access and Video Surveillance Security System, Access control panels, Proximity readers, Motion request-to-exit devices, Exit buttons, Desk door-release buttons, Magnetic locks, Electric strikes, Prox cards, WV-S25500-F6L indoor/outdoor PoE cameras, Five-port PoE network switches, Video-i. Proposals should clearly address how each deliverable will be met.
Show 5 more questions
What are the evaluation criteria for this solicitation?
This solicitation includes specific evaluation criteria that will be used to score proposals. The criteria include: "Experience (20 Points), Project Design (20 Points), Cost Efficiency (40 Points), Program Operations (20 Points)" Vendors should carefully align their proposals with each criterion to maximize their score.
Where can I find more RFPs from Holmes County Consolidated School District?
All active and historical solicitations from Holmes County Consolidated School District are tracked and searchable. As a school agency, Holmes County Consolidated School District regularly publishes solicitations. Visit the agency profile to see current open bids, past contracts, vendor relationships, and decision-maker contacts.
Is this solicitation still open for submissions?
Based on the posted deadline of December 4, 2026, this solicitation appears to still be accepting submissions. Deadlines may change through amendments or addenda, so always verify the current status directly with the issuing agency before preparing your response.
What documents are required to bid on this RFP?
Requirements vary by solicitation, but common documents include a technical proposal, cost/price proposal, proof of insurance, relevant certifications, past performance references, and any forms specified in the solicitation. This solicitation specifically requires the following attachments: Vendor Profile, Production Proposal, Implementation Plan, Budget narrative/cost proposal, manufacturer model numbers and quantities, installation schedule and estimated duration, bidder's relevant exp. Review the full document from Holmes County Consolidated School District for the complete list.
What is the scope of this project?
This solicitation defines a specific project scope. The scope covers the following locations: Lexington, MS. Review the full solicitation for detailed scope requirements.